Local Authority Submission

Local Authority Submission

Professional Engineering consultancy for the design of pollution control equipment (stack, scrubber, bag filter, local exhaust ventilation) complying with DOE and DOSH Written Notification & Written Declaration (Pemberitahuan Bertulis & Penisytiharan Bertulis) requirement.

Submission of Written Notification, Written Declaration and As-built drawing as required by DOE regulation below:

Under regulation 7 (1) of the Environmental Quality (Clean Air) Regulation 2014, every premises shall be equipped with an air pollution control system in accordance to the specifications as determined by the Director General.

Under regulation 5 of the Environmental Quality (Clean Air) Regulation 2014, the industry is required to do ‘Written Notification’ (Pemberitahuan Bertulis) to the Department of Environment prior to the implementation or installation of the following:

Written Notification on Air Emission Sources (Fuel Burning Equipment)

Written Notification on Air Emission Sources (Incinerator)

Written Notification on Air Emission Sources (Air Pollution Control System) (Scrubber)

Written Notification on Air Emission Sources (Air Pollution Control System) (Bag Filter)

Written Notification on Air Emission Sources (Air Pollution Control System) (Centrifugal Dust Collector)

Written Notification on Air Emission Sources (Air Pollution Control System) (Centrifugal Dust Collector) (Axial-Flow Vortex Tubes)

Written Notification on Air Emission Sources (Air Pollution Control System) (Spray Booth)

Written Notification on Air Emission Sources (Air Pollution Control System) (Electrostatic Precipitator ESP)

Written Notification on Air Emission Sources (Generator)

Written Notification on Air Emission Sources (Incinerator)

Written Notification on installation of Exhaust / Vent

Emission Declaration of Air Emission Sources (Under regulation 18)

Under regulation 7 (2) of the Environmental Quality (Clean Air) Regulation 2014, an owner or occupier of the premises shall appoint a Professional Engineer (Registered with BEM) to design and supervise the construction of the air pollution control system.

Under regulation 7 (5) of the Environmental Quality (Clean Air) Regulation 2014, the owner or occupier of the premises and the Professional Engineer shall, within thirty days after the commencement of the operations at the premises, submit a Written Declaration (PENISYTIHARAN BERTULIS) to the Director General, in such form as determined by the Director General, certifying that the design and construction of the air pollution control system have complied with the specifications referred to in sub-regulation (1).

Under regulation 7 (6) of the Environmental Quality (Clean Air) Regulation, 2014, the owner or occupier of the premises shall, within thirty days after the commencement of the operations at the premises, submit to the Director General, as-built drawings that show the placement of any works or structures that form part of the air pollution control system.

Scope of Services

1. Department of Environment Malaysia (DOE)

Written Notification & Written Declaration for Pollution Control equipment to DOE (Jabatan Alam Sekitar)

Written Notification & Written Approval for Industrial Effluent (Wastewater) Treatment System (IETS)

Approval for installation of chimney, scrubber, dust collector, bag Filter and Fuel Burning equipment

Preliminary Site Assessment (Penilaian Awal Tapak) (AS-PAT)

Environmental Impact Assessment (EIA)

Environmental Management Plan (EMP)

Special Waste Management

Design, Supply and Installation of Continuous Emission Monitoring System (CEMS)

2. Department of Occupational Safety and Health (DOSH) Malaysia

Chemical Health Risk Assessment (CHRA)

Chemical Exposure Monitoring

Local Exhaust Ventilation (LEV) Testing

Indoor Air Quality (IAQ)

WhatsApp chat